Specification:
CZPT: | IEC60034 | ||
Frame Measurement: | H80-H355 | ||
Power: | .75-300KW | ||
Rated Voltage: | 380V,400V,415V | ||
Rated Frequency: | 50HZ,60HZ | ||
Poles: | 4 | ||
Speed: | 1000-300r/min | ||
Existing: | 1.five-40A | ||
Efficiency Class: | IE2 | ||
Insulation Course: | F | ||
Defense Course: | IP54 IP55 | ||
Cooling Approach: | IC411 | ||
Ambient Temperature: | -15°C-+40ºC | ||
Mounting: | B3,B35 | ||
Responsibility: | S1 | ||
Frame Substance: | Cast Iron/Aluminum | ||
Terminal Box: | Prime or Side | ||
Altitute: | ≤1000m | ||
Certification: | CE 3C CZPT |
Description:
The prolong shaft motor adopts the design technologyand is created of warmth-resistant insulating supplies. It can guarantee the safe operation of the motor in substantial-temperature enviroment CZPT getting older and burning. Its motor functionality is created according to the traits of admirer and pumb load, which can preserve strength and adopt reinforced insulation to make sure dependable insulation and boost services existence.
Bulletins:
one.You should validate whether or not the physical appearance of the motro is broken prior to ues? Is there any oil leakage?
2.Please verify the voltage of the motor. Voltage regulator can be set up whne voltage is unstable.
three.Please validate regardless of whether the speciation of the motor obtained is steady with the design and style specification.
four.Remember to make certain that the body is mounted to avoid loosening in the course of procedure.
5.If sprocket, pulley,coupling are utilized and other accessories must be installed in accordance to pertinent regulation.
6.The lubricating grease has been put into the body of the decelerating motor, and the lubricating oil can not be transformed for 12000 hrs.
seven.When the motor is running, the rated current shall not exceed the present benefit indicated on the motor nameplate.
8.You should shell out focus to the surrounding temperature, humidity, pH and other issues.
9.If it is not installed or operated in the proper way, it might cause severe damage to the motor.
10.During maintenance or disassembly, it is necessary to confirm that the external energy supply is entirely folded away from the motor.
11.The protection security device should be set up to make certain the security of operation.
twelve.The motor requirements grounding wire, please refer to related electricity distribution.
13.Make sure you validate that all set up elements and transmission equipment are fastened correctly beforestarting the deceleration motor.
fourteen.If the motor is driven with frequency converter at lower velocity, it is needed to set up the auxiliary cooling admirer.
15.Remember to advise the complex division of our manufacturing unit when the motor is mounted vertically.